Although the advantages of rigid PVC drainage pipes are very significant, there are still some objective problems in the design and construction use:

1. Temperature influence

UPVC pipe has poor heat resistance, and its tensile strength decreases above 60°C (applicable to domestic sewage whose continuous discharge temperature does not exceed 40°C and instantaneous discharge temperature does not exceed 80°C). Therefore, the design and use should be far away from the heat source, such as the distance from the stove edge is greater than or equal to 400mm, and the distance from the hot water pipe is greater than or equal to 200mm. At the same time, the hot water pipe should be insulated and must not pass through the flue and firewall.

The impact strength of rigid PVC drainage pipes is reduced in low temperature environments. Therefore, in the conversion layer of equipment with air conditioning, cast iron pipes can be considered instead of hard polyvinyl chloride drainage pipes to ensure drainage safety.

Due to the large temperature influence and large expansion coefficient, expansion joints are required on each layer of riser pipes and longer horizontal pipes. Therefore, other professional layouts should consider the notch effect of UPVC pipes. When laying parallel to other pipes, the plastic pipes should be sideways. When laying crosswise, the plastic pipes should be placed under and staggered, and metal casing should be considered for protection. In addition, the position where the riser passes through the floor roof should be used as a fixed support point, and a flexible sheath should be installed.

2. Stiffness influence

UPVC pipe

UPVC pipe

There should be a firm fixing bracket for each layer of the riser. The fixed bracket can not only control the expansion direction of the pipeline, but also share the weight of the riser, and also prevent the pipe head connecting the riser and the exit horizontal pipe from being excessively stressed, causing The pipe is broken and leaking, and at the same time, fixing measures such as buttresses or hangers should be installed at the bottom of the riser.

In outdoor construction, UPVC pipes are particularly vulnerable to damage. When the UPVC and the outdoor integrated pipe network are cross-constructed, manual and mechanical equipment are sufficient to cause different degrees of damage to it, and even smash or break to cause the pipeline to be blocked. When the pipeline is backfilled, UPVC pipes are often damaged due to partial overhead of the pipeline or compression by larger hard objects. Therefore, the buried UPVC pipe requires that after the base is tamped, there is 100mm under the pipe and 300mm backfill sand above the pipe, and the total buried depth is not less than 900mm.

3. Building fire protection

China's research on PVC plastic flame retardant technology generally has a tendency to one-sidedly pursue the improvement of oxygen index and ignore the research on smoke generation performance. Statistics show that 79% of fires are fatal by smoke. Some UPVC pipes have an oxygen index of more than 50%, but they emit a lot of smoke during combustion, and the Vicat temperature is only between 70°C and 90°C. Therefore, although UPVC pipe is difficult to burn, it is easy to soften and deform, and the smoke smell is very strong. On the one hand, lethal smoke is produced in the fire. The higher the wind speed of the drainage pipe or vent pipe passing through the roof, the faster the fire will spread. Therefore, whether or not UPVC pipes can be used in high-rise buildings has been a matter of debate, and the focus of the debate is its fire-resistant properties.

UPVC pipes have been widely used in high-rise buildings, but the above-mentioned fire protection problems have not been paid enough attention, and no opinions on the installation of UPVC pipes have been put forward during the fire protection special inspection and acceptance. Due to the current "Code for Design of Building Fire Protection" GB 50016-2014, "Rigid PVC Pipes for Building Drainage" GB /T5836. 1-92 and "Technical Specifications for Building Drainage Rigid Polyvinyl Chloride Pipe Engineering" CJJ-96 and other specifications are not Clearly stipulate how to use UPVC pipes, making this problem "out of order". While calling for the promulgation of relevant national documents and regulations, some opinions are put forward for colleagues' reference: (1) Rain, sewage, and ventilation risers should be installed along the outer wall of the building as much as possible. (2) When rain, sewage, and ventilation risers are in the building, they should be installed in the pipeline well, or protected by non-combustible materials such as bricks and concrete blocks. (3) The branch pipes that drain into the drainage standpipe shall be metal drainage pipes, or strict fire protection measures shall be taken for the branch pipes, such as steel casing pipes and inorganic fire casing pipes. (4) Metal products should also be used as much as possible for drainage accessories.

In addition. UPVC drainage pipes still have issues such as standpipe energy dissipation, noise reduction and prevention of condensation, all of which limit the promotion and use of existing UPVC drainage pipes to a certain extent.